Afdd Afci General Purpose Circuit Breaker Arc-Fault Circuit Interrupter FAFDD

FAFDD fault arc protector is composed of small circuit breaker and fault arc protection module. It has overload, short circuit and arc fault protection and other protection functions.
FAFDD arc fault protector is suitable for AC 50HZ, rated voltage 230V, rated current to 63A and below lines, used for building and similar lines for over-current protection, and can detect the fire risk caused by electrical device rupture or wire aging in advance. Protection against ground arc faults, parallel arc faults and series arc faults. It can reduce the occurrence of fire safety accidents to a certain extent, and provide effective protection for people's lives and property safety.
  • FAFDD

  • KCISE

Availability:
Quantity:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button

Introducing the Afdd Afci General Purpose Circuit Breaker Arc-Fault Circuit Interrupter AFDD, a cutting-edge solution designed to enhance electrical safety in residential and commercial settings. This innovative product combines advanced arc-fault detection technology with reliable circuit breaker functionality, providing a comprehensive safeguard against electrical hazards. With its professional-grade construction and superior performance, the Afdd Afci General Purpose Circuit Breaker Arc-Fault Circuit Interrupter AFDD offers peace of mind and protection for your electrical systems. Trust in this top-of-the-line product to ensure the safety and efficiency of your electrical infrastructure.


◎   Ambient air temperature: The ambient air temperature is not higher than +70° C, not lower than -5° C, the average value of 24 hours is not more than +35° C, and the FAFDD arc fault protection circuit breaker used in the ambient air temperature is higher than +70 C or lower than -35C should be negotiated with the manufacturer

◎   Sea level: The sea level of the installation site does not exceed 2000m

◎   Atmospheric conditions: the  relative  humidity of the atmosphere does not exceed 50% when the maximum temperature around +60'C, and can have a higher relative humidity at a lower temperature, such as 90% at 20C, for condensation occasionally caused by temperature changes, protective measures should be taken

◎   Installation conditions: The external magnetic field near the installation site of the arc fault protector should not exceed 5 times of the earth magnetic field in any direction; The installation position should be vertical, and the inclination of each direction should not exceed 10%; Installed in a place without shock vibration and without rain and snow attack; Standard TH35-7.5 steel mounting rail is adopted for installation

◎   Pollution level: Level 2

◎   Installation category: Class III

◎   Protection level :IP20(installed in the distribution box, distribution cabinet or box IP40) with N pole products, wiring, must be connected to the neutral line marked with N pole



Type of transient

overcurrent trip

device


Rated current

InA

 Test current

A

 Initial state

 Test time

Expected

result


Notes appended to a

book


Key temperature

accuracy

C

≤ 20

1.13In


Cold state

t ≤ 1h

 non-trip

-

30℃ ~35℃

C

1.45In

Immediate test

t<1h

 trip

 The current rises to the   specified value within 5S

C

2.55In

Cold state

1s<t<60s

 trip

-

C

5In

Cold state

t ≤ 0.1s

 non-trip


Closing auxiliary switch

Power on

C

10In

冷态

Cold state

t<0.1s

脱扣 trip


Closing auxiliary switch

Power on

b. Electrical life: 4000 times

c. Isolation function


电弧保护

Fault analysis and elimination of FAFDD arc fault protector

Fault cause

 Fault analysis

Troubleshooting

Miss motion


FAFDD protector is not

connected to the neutral line

caused by rejection


The power supply side of the FAFDD protector is only

connected to the phase line, not the neutral line


Connect the neutral cable on the power side

maloperation

 FAFDD protector tripping

The L and N wires at the incoming and outgoing

ends of the FAFDD protector cross


In strict accordance with the wiring drawing and its products pad printing access circuit


Zhejiang Shanmeng Electric Co., Ltd. is located at Wenzhou city Zhejiang province China. Founded in 2003, the company has a registered capital of ten million yuan.

Quick Links

Product

Contact Us

 No.656, Lehu Road, Shahu Industrial Zone, Liushi town, Yueqing, Zhejiang , 325604, P.R.China
 +86 189 6970 2309
 +86-577-61783566
Copyright © 2024 Zhejiang Shanmeng Electric Co., Ltd. All Rights Reserved.| Sitemap